Sterilization Control

Download technical boards and the catalogue pages of all E.C.S. s.r.l. products.

EC.STEAM 98

EC.STEAM 98 S

EC.STEAM 98.1-L

EC.STEAM 98.1/E

BOWIE & DICK PACK

Sterilization Control

  • Air leaks inside the autoclave represent a serious threat for the validation of the sterilization process. However, this problem can be solved through the daily use of the Bowie & Dick test pack, as provided by international standards in force.
  • Disposable pack for the daily Bowie & Dick test is suitable for the control of steam penetration and air removal from the autoclaves during steam sterilization.
  • Unlike traditional devices, the use of Bowie & Dick test pack offers consistent advantages that ensure the validation of each test and the immediate detection of air removal during the sterilization.
  • Bowie & Dick test pack is a safe and reliable product.
  • It can immediately detect any problem occuring during the Bowie & Dick cycle.
  • Test sheet will remain flat after the sterilization cycle.
  • External chemical indicator permits the prompt identification of processed packs.
  • The materials are full recyclable and the process indicator is non-toxic
  • Full conformity to standards in force.
  • Easy-to-read test sheet clearly identifies failures and can be filed for record keeping.
  • 20 pcs/pack

EC.STEAM 98.2

EC.STEAM 98.2 - BOWIE & DICK TRADITIONAL SHEET

Sterilization Control

  • Disposable traditional sheet for the daily Bowie &Dick test is suitable for the control of steam penetration and air removal from autoclaves during steam sterilization.
  • Each sheet provide lot number, date of production, expiring date, supplier’s name and brand, product code and data records
  • Test sheet will remain flat after the sterilization cycle.
  • The materials are full recyclable and the process indicator is non-toxic
  • Full conformity to standards in force.
  • Traditional sheet dimensions: 50 pcs/pack - 1000 pcs/box

HELIX TEST SYSTEM

HELIX TEST

Sterilization Control

  • Helix test evaluates the capacity of penetration of the sterilization agent (steam, VH202, EO, formaldehyde) inside hollow loads.
  • Air and any other non-condensing gases shall be removed from the sterilization chamber before the sterilizing agent comes into contact with the devices to be processed so that the test result is not adversely affected
  • The Helix test is s suitable for every sterilization process in a loaded autoclave
  • Suitable to be used with all types of autoclaves.
  • Full conformity to standards in force.
  • N. 1 Helix with 25, 50, 100, 250 strips.

EC.STEAM 98.4

EC.STEAM 98.4 - STEAM STERILIZATION INTEGRATOR

Sterilization Control

  • Integrators for the control of steam sterilization. Integrators evaluate the effectiveness of the process and exposure to sterilization parameters (time – temperature – saturated steam concentration) to fulfill the seam sterilization cycle at 121°C and 134°C.
  • Integrators are completely laminated to prevent ink from migrating to the product and to preserve test result
  • Reliable and easy to use. Non-toxic chemical indicator
  • Full conformity to standards in force.
  • Class 4
  • 250 pcs/box.

EC.STEAM 98.3L

EC.STEAM 98.3L - STEAM STERILIZATION INTEGRATOR

Sterilization Control

  • Integrators for the control of steam sterilization. Integrators evaluate the effectiveness of the process and exposure to sterilization parameters (time – temperature – saturated steam concentration) to fulfill the steam sterilization cycle at 121°C and 134°C.
  • Integrators are completely laminated to prevent ink from migrating to the product and to preserve test result
  • Reliable and easy to use. Non-toxic chemical indicator
  • Full conformity to standards in force.
  • Class 5
  • 250 pcs/box

PERFORMER

PERFORMER - SEQUENTIAL INTEGRATOR

Sterilization Control

  • Three phase sequential integrator for the control of steam sterilization both in high vacuum or gravity air removal autoclaves . Suitable for steam sterilization cyles at 121°C and 134°C.
  • PERFORMER indicator is completely laminated to prevent ink from migrating to the product and to preserve test result
  • Thanks to its three process indicators, PERFORMER is more than a simple indicator. The first indicator turns its color to confirm the beginning of the sterilization process, the second indicator turns its color to confirm the end of the sterilization process, the third indicator turns its color to exhibit over-exposure.
  • Under normal conditions all three indicators completely turn their color during sterilization process. In case the third indicator doesn’t change, the operator shall ask for autoclave technical assistance.
  • Non-toxic chemical indicator
  • Full conformity to standards in force.
  • Class 5
  • 250 pcs/box

PERFORMER-E

PERFORMER-E - SEQUENTIAL EMULATOR

Sterilization Control

  • Class 6
  • 250 pcs/box

EC.PRION 98.6

EC.PRION 98.6 - SEQUENTIAL EMULATOR

Sterilization Control

  • Sterilization emulator integrator evaluates the effectiveness of the sterilization process and exposure to sterilization parameters (time – temperature – saturated steam concentration)
  • Steam sterilization cyles at 134°C for 18 minutes.
  • Heat-resistant paperboard
  • Non-toxic chemical indicator
  • The printed side of the indicator is completely laminated to prevent ink from migrating to the product and to the operator
  • Class 6
  • 250 pcs/box.

EC.PLASMA

EC.PLASMA - VH2O2 INTEGRATOR

Sterilization Control

  • Chemical indicator to be used inside each load to be sterilized.
  • The chemical indicator evaluates the effectiveness of the sterilization process and exposure to VH202 sterilization
  • Non-toxic chemical indicator will change its color to identify processed packsat a glance
  • Full conformity to standards in force.
  • Class 4
  • 250 pcs/box.

EC.OXIDE 98.E1L

EC.OXIDE 98.E1L - EO CHEMICAL INTEGRATOR

Sterilization Control

  • Chemical integrator EC-OXIDE 98.E1L is a laminated paperboard strip suitable for EO sterilization
  • Chemical EO indicator evaluates the effectiveness of the sterilization process and exposure to sterilization parameters (temperature - time -EO concentration)
  • Chemical indicator will turn its color upon exposure to EO sterilization cycle
  • Non-toxic chemical indicator
  • Full conformity to standards in force.
  • Class 5
  • 250 pcs/box.

EC.FORM

EC.FORM - FORMALDEHYDE CHEMICAL INDICATOR

Sterilization Control

  • The chemical indicator evaluates the effectiveness of the sterilization process and exposure to Formaldehyde sterilization
  • Non-toxic chemical indicator will change its color to identify processed packs at a glance
  • Full conformity to standards in force.
  • Class 4
  • 250 pcs/box.